Data IntegrationKnowledge center
Technical notes from the field
Articles from seven areas of expertise: configuration mistakes, field scenarios and solution steps in systems, networking, security and enterprise IT infrastructure.
Data Integration
Industrial EthernetZero-Interruption Network Redundancy with HSR and PRP: When Is It Needed?
How do HSR and PRP work? IEC 62439-3 frame duplication, RedBox and QuadBox, bandwidth and PTP constraints, pitfalls in the field and a decision tree versus MRP/RSTP.Industrial Networks / IT-OT · 10 March 2026 · 10 min readRead more
OT Security and SegmentationModbus and S7 Deep Packet Inspection Rules on Industrial Firewalls
Writing DPI rules by Modbus function code, register range and S7comm function; the address offset mistake, and steps for a safe transition from learning mode to enforcement.Industrial Networks / IT-OT · 6 March 2026 · 9 min readRead more
Data IntegrationData Modelling with the OPC UA Information Model and Companion Specifications
How an OPC UA information model is built in the field: address space, node classes, ObjectTypes, references, Companion Specifications, NodeSets and common mistakes.Industrial Networks / IT-OT · 23 February 2026 · 11 min readRead more
Industrial EthernetPROFINET MRP Ring Topology: Roles, Watchdog and Ring Break Testing
How is a PROFINET MRP ring set up? MRM/MRC roles, the 200 ms profile and watchdog alignment, how it differs from RSTP, common ring mistakes and planned break test steps.Industrial Networks / IT-OT · 9 February 2026 · 13 min readRead more
OT Security and SegmentationHow to Design an OT DMZ: Which Server Goes Where?
In OT DMZ design: the ban on direct sessions, single/dual firewalls, placement of historian, WSUS, jump host and SFTP; common rule mistakes and a checklist.Industrial Networks / IT-OT · 9 February 2026 · 11 min readRead more
Data IntegrationOPC UA or MQTT? The Right Protocol for Production Data
Every new client connected to a PLC increases the communication load. What OPC UA and MQTT do at which layer, an architecture for using them together, and common configuration mistakes.Industrial Networks / IT-OT · 22 January 2026 · 7 min readRead more
Industrial EthernetChoosing an Industrial Switch: How It Differs from an Office Switch
The temperature, vibration, power supply and electromagnetic environment inside the cabinet must be compared with the technical limits of the switch to be used. Temperature, power, ring protocol, IGMP, management and lifecycle criteria for choosing an industrial switch.Industrial Networks / IT-OT · 8 January 2026 · 7 min readRead more
OT Security and SegmentationThe Zone and Conduit Approach in IEC 62443
The definition of zones and conduits in IEC 62443, risk assessment under IEC 62443-3-2, target security level (SL-T) and a practical starting plan for the factory.Industrial Networks / IT-OT · 6 January 2026 · 7 min readRead more
OT Security and SegmentationIT/OT Network Separation with the Purdue Model: A Practical Start
If production devices need to be reached from the office network, it must be defined who uses the flow, for which service and through which control point. Purdue levels, an industrial DMZ and a phased migration carried out in planned windows.Industrial Networks / IT-OT · 8 December 2025 · 8 min readRead more
Industrial EthernetCommon Mistakes in PROFINET Network Design
Design mistakes that can cause intermittent PROFINET dropouts: office switches, rings without MRP, mixed traffic, faulty grounding and naming. The mistakes and how to fix them.Industrial Networks / IT-OT · 8 December 2025 · 7 min readRead more